A.4.10 Environmental specifications
Operating temperature range
Switch-on extended operating
temperature class
Cooling
Storage temperature
Relative atmospheric humidity
Altitude class
Pollution degree conformance
Shock and Vibration
"Categories & Classes":
Rapid temperature variation
class
Conformal coating type
Fire behavior compliance
Teldat 5Ge-Rail Router
EN 50155 OT3: –25 to +70 °C.
EN 50155 ST1: OTx +15 °C.
Natural cooling, non-forced ventilation constraints for the equipment are neces-
sary.
min. -40 °C max. +75 °C.
EN 50155: 95 %. max.
1400 meters max.
PD2
Category 1 Class B of EN 61373
H1
PC1
According to EN 45545-2
Technical Information