Page 2
This publication is subject to change. Teldat S.A. offers no warranty whatsoever for information contained in this manual. Teldat S.A. is not liable for any direct, indirect, collateral, consequential or any other damage connected to the deliv- ery, supply or use of this manual.
1 About This Guide Teldat S.A. Chapter 1 About This Guide This is the installation guide for the Teldat 5Ge-Rail router and contains information on how to correctly install the device in a working environment. 1.1 Supported Devices The information included in this installation guide specifically pertains to the Teldat 5Ge-Rail router.
1 About This Guide Teldat S.A. 1.7 Technical Support In order to ensure optimal performance and stay up-to-date with the latest features, Teldat S.A. provides technical support and regular software upgrades. Contact information: Web: http://www.teldat.com Tel.: +34 918 076 565 Fax: +34 918 076 566 Email: support@teldat.com...
5. 2.2 Hardware Monitoring The Teldat 5Ge-Rail router features a LED panel for hardware monitoring purposes. These LEDs offer visual cues about the device's operational status and indicate connectivity, data flow, and other relevant information. For additional details about the LED panel, please refer to Components on page 5.
3 Components and Power Supply Teldat S.A. Chapter 3 Components and Power Supply The following chapter provides comprehensive information about the chassis and components of the Teldat 5Ge-Rail router, including details about: • Front and rear panel components. • Assembly procedures.
Page 10
Connecting the WWAN antennas on page 13 WWAN antenna connector on page 26 Wireless WAN interface on page 29 In addition to the connectors, the front panel also features a set of LEDs that provide information on the router's status. Teldat 5Ge-Rail...
Red -> No SIM Selected. Amber -> SIM2 Selected. Green -> SIM1 Selected. 3.1.2 Rear panel Moving on to the rear panel, as illustrated in the following figure, the Teldat 5Ge-Rail SIM card slots can be found here. Rear Panel Fig. 3:...
3.2.1 Assembly: Recommendations Thanks to the mounting brackets, the Teldat 5Ge-Rail can be easily mounted on either the wall or ceiling. Wall-/Ceiling mounting To install the device in this manner, the mounting brackets can be readily attached to the housing. They are screwed to the wall/ceiling using six screws.
Before connecting the router, please carefully read the instructions provided below! 3.3.1 Connecting the power supply To power the Teldat 5Ge-Rail, it supports a 24 V to 110 V nominal DC power source. Note It is important to ensure that the power input of the device is compatible with your power source.
Page 14
DC connection, as connecting it incorrectly may result in damaging the external line fuse. The Teldat 5Ge-Rail is equipped with one earth terminal located on the rear pan- el. It is essential to ground it using a cable with a section measuring at least 2 mm (AWG14).
3.3.2 PoE The Teldat 5Ge-Rail device can be powered through an Ethernet cable, but only if the cable complies with the POE 802.3at standard (PoE+). The LAN1 port on the device is designed to support this type of power delivery.
• Router: If the device has a router license, it will function as a router. In this case, the default configuration will es- tablish the following access IP address and mask: IP address: 192.168.1.1 IP mask: 255.255.255.0 Teldat 5Ge-Rail...
Antenna connectors and bands on page 29. Installing these antennas in the Teldat 5Ge-Rail is essential to improve the quality of the signal received and trans- mitted by the cellular model. Note It is crucial to install WWAN antennas in the Teldat 5Ge-Rail router in order to enhance the signal qual- ity received and transmitted by the cellular module.
3.5.3 Connecting the GPS antenna The Teldat 5Ge-Rail is equipped with a QMA connector that allows for the connection of an active GPS antenna. However, it should be noted that since the router lacks internal antennas, installing an active 3.3V external antenna on the Teldat 5Ge-Rail is necessary to enhance the quality of the GPS signal.
3.5.4.1 Configuration using the local console (CONF connector) The Teldat 5Ge-Rail features an M12 8P A-Code female connector on the front panel. This connector serves two purposes: providing access to the router's local console and functioning as an asynchronous serial port. Please refer to the following image for the location of the CONF connector.
Teldat 5Ge-Rail (specifically the LAN1 connector). • Open a Telnet session from the IP terminal to the default IP address of the Teldat 5Ge-Rail, which is 192.168.1.1. • Note that the default configuration does not require any login credentials (username/password) to access the con- sole.
The Teldat 5Ge-Rail router features a Wireless WAN interface that requires one or two SIM cards for operation. On the front panel of the Teldat 5Ge-Rail , you will find two protected SIM trays, as shown in the following figure.
Parque Tecnológico de Madrid, 28760 Tres Cantos, Madrid, Spain International Phone +34 91 807 65 65 4.2 Risk Identification WARNING: This signal word is used to indicate a potentially hazardous situation that could result in serious injuries or death if not avoided. Teldat 5Ge-Rail...
0.1% weight by weight (w/w). This declaration will be regularly updated to re- flect any changes or additions to the REACH Candidate List. Further information is available to consumers upon re- quest. Teldat 5Ge-Rail...
Please be aware that these re- quirements can change over time. Teldat S.A. strongly recommends consulting local authorities to stay up to date with the current national regulations.
IP address of your computer is configured to match the subnet of the router. A.2 Maintenance Teldat 5Ge-Rail routers are specifically designed to ensure high availability and durability, and for this reason they are built without any moving parts. This design eliminates the need for regular maintenance and enhances their overall reliability.
In terms of protecting the metal housing, the Teldat 5Ge-Rail router was purposely designed to be kept in an en- closed space, shielded from harsh weather conditions, and never exposed to extreme environmental factors.
To upgrade the Wireless LAN module, you will need the appropriate UPGRADE file, which can be obtained from your dealer based on the module in your device. You can refer to the “Teldat Dm 781-I Cellular Interface” manual for instructions on how to UPGRADE the module.
Technical Information Teldat S.A. BI-DC+(8) A.3.3 WWAN antenna connector The Teldat 5Ge-Rail router is equipped with up to four QMA female connectors. Internal RF in/out External A.3.4 GPS connector The GPS connector installed on the router is a QMA female connector.
• Acquisition: -145 dBm Sensitivity • Tracking: -162 dBm • Reacquisition: -152 dBm Dynamic Performance • Maximum Altitude: 18000 m • Maximum Velocity: 515 m/s • Maximum Acceleration: 4g Connector QMA female. Antenna 3.3 V active or passive. Teldat 5Ge-Rail...
Switching power 30 W d.c. Insulation voltage 1500 V d.c. Control to contact. Connector M12. Comments Relay Contact. Surge protection is highly recommended when connecting to power sources to en- sure the safety and reliability of the device. Teldat 5Ge-Rail...
According to 802.3at (PoE+) on LAN-1 (> 5 °C only) For safe operation, the Teldat 5Ge-Rail devices have a protective earth connection. The earth lead should have a minimum cross-section of 2.5 mm and the distance between the device and the earth connection should be as short as possible.
EN 50155: 95 %. max. Altitude class 1400 meters max. Pollution degree conformance Shock and Vibration Category 1 Class B of EN 61373 “Categories & Classes”: Rapid temperature variation class Conformal coating type Fire behavior compliance According to EN 45545-2 Teldat 5Ge-Rail...
The conformity assessment procedure, as mentioned in Article 17 and detailed in Annex III of Directive 2014/53/EU, has been verified for the Teldat 5Ge-Rail with Regulatory Model "TLDPH00M1". This verification is based on the use of the following technologies and bands: •...
Need help?
Do you have a question about the 5Ge-Rail and is the answer not in the manual?
Questions and answers