8.6.3 Using the CLO features

8.6.3.1 CLO feature in the OSD, Prospector and API

CLO feature in the OSD
Navigate to Installation — Illumination
Image 8–1
CLO feature from Prospector
Navigate to Settings — Illumination
Image 8–2
CLO feature from API
illumination.clo.engage
-
Enables the CLO and creates a new set-point for the CLO
illumination.clo.enable
-
Enable the CLO: "value":true
-
Disable the CLO: "value":false
-
This command enables the CLO while keeping the previous set-point for the CLO

8.6.3.2 Notifications applicable for the CLO feature

Info
L8000b Illumination clo mode {0}
-
Modes: Enabled or Disabled
L8000c Illumination CLO target set to 0
-
Value refers to the set-point of the CLO
Warning
L8000a Illumination clo unable to maintain the desired light output
-
Explanation: The light source power is at its maximum and can no longer maintain the desired light
output
L8000d Illumination cli light measuring failed
-
Explanation: The CLO failed while trying to measure the light on the light sensor, either when enabling
the CLO or during CLO operation