System settings menu
If you are using a DMX console and other automated lighting products compatible with Art-Net, the Ethernet
network can serve as the link for DMX control. All DMX controls can be sent over the Ethernet cable. Multiple
universes are possible.
About the DMX menu
DMX Feature What can be done?
DMX Address
Before a projector can execute DMX commands, a unique address (named "Start Channel")
should be given to the projector.
(Start
Channel)
This address can vary from 1 to 512.
DMX Mode
Two different modes for DMX are available.
DMX Monitor
If a DMX device is connected, the settings per channel can be displayed via the Monitor
button.
Art-Net DMX
DMX can be sent via the Ethernet connector to the projector instead of the classic DMX
connector. This function can be enabled or disabled. Art-Net is generally used when more
than 512 addresses are used in your setup.
DMX
Note: DMX Universe can only be used when Art-Net DMX is enabled.
Universe
If Art-Net is enabled, you can specify to which DMX universe this projector belongs to.
DMX Power
The projector can be forced to shut down after a certain time-out period (in minutes) if no
Down
DMX signals are available.
For full mapping of each used channel, refer to the DMX chart in the appendices, see User guide.
How to set up DMX?
1.
In the main menu, select Settings / Communications / DMX.
Image 10–9
The DMX menu is displayed.
Image 10–10
152
601–426 /15
F70 Series
Basic: A basic configuration where 2 channels are implemented.
Extended: A full configuration, spread over 14 channels.

Advertisement