32
7

Settings

NOTE
You will find a table containing all the relevant switch positions on the
back of the stator cover. Changes to the factory settings should be
noted here using a waterproof felt‐tip pen.
Einstellungen
Impulse/Umdrehung
Pulses/revolution
M
nom
15 kNm
to
80 kNm
0
+
-
Hysterese
Hysteresis
Frequenz
Ausgangsspannung
Frequency output
voltage
Fig. 7.1: Sticker with switch positions

7.1 Torque output signal

The factory setting for the frequency output voltage is 5 V (symmetrical,
complementary RS-422 signals). The frequency signal is on pin 4 opposite
pin 1. You can change the output voltage to 12 V (asymmetrical). To do this,
change switches S1 and S2 to position 1 (see Fig. 7.2 and pin 1 
HBM
/ Settings OPTION 4
360
720
180
ein / on
CH1
CH2
90
60
30
aus / off
CH1
CH2
T10FM
15
2 x f
).
A0894-5.2 en