Hardware Errors; Table A-1 Hardware Errors By Error Code - Sun Microsystems SPARCstorage Library User Manual

Hide thumbs Also See for SPARCstorage Library:
Table of Contents

Advertisement

A
A.1 Hardware Errors
Error
Description
Number
10
CHM dropped a cartridge.
11
Source empty. There is no cartridge
in the source location.
12
Destination full. A cartridge already
exists in the destination location.
13
Put mechanical failure. The CHM
could not place a cartridge due to
mechanical problems.
14
Pick mechanical failure. The CHM
could not pick a cartridge due to
mechanical problems.
15
No source element.
16
No destination element.
17
CHM full before move. A cartridge
was in the gripper in one of these
circumstances:
- at power-on
- when reset
- before a move operation
19
Pick mechanical failure. The CHM
could not successfully pick from a
full cartridge slot.
21
Gripper error.
A-2
Table A-1 presents the hardware error conditions in numerical order. The error
code number appears on the display panel during either normal operation or
diagnostic operation.

Table A-1 Hardware Errors by Error Code

Corrective Action
Put the cartridge back in the data cartridge magazine. Do not try to
put the cartridge back in the gripper. The tape library will not start
if there is a cartridge in the gripper. Reset the tape library.
Install a cartridge in the source location or redirect the CHM to
another location.
Remove the cartridge from the destination or redirect the CHM to
another location.
Reset the tape library. If this error still occurs, replace the tape
library.
Reset the tape library. If this error still occurs, replace the tape
library.
A data cartridge was not installed at the selected location.
A data cartridge was not installed at the selected location.
Remove the cartridge. Put the cartridge back in the data cartridge
magazine. Make sure the tape library and the tape drives are not
being used by the host computer then reset the tape library.
Reset the tape library. If this error still occurs, replace the tape
library.
Reset the tape library. If this error still occurs, replace the tape
library.
SPARCstorage Library X-Option Rack-mounted User's Guide—June 1995