1.4 Resuming the Tape Library's Operation
1.5 Resetting the Tape Library
!
1.6 Security Options for the Tape Library
1. Close the tape library's door.
2. Turn the key counterclock wise in the door lock to lock it.
After the door is closed, Unit Attention status is returned to the host. The
tape library then performs its initiation procedure.
Note – You will get a Status: error 91 operator abort message.
Reset the tape library after you have finished correcting a hardware error.
Hardware errors can include problems in picking and placing a cartridge, or
difficulties in moving the CHM. When a hardware error occurs, a message
appears on the LCD describing the error.
To reset the tape library:
Press Reset, then Enter on the Operator Panel.
A reset causes the tape library and the drives to perform their initiation
tests. After the tape library is reset, the Main Screen appears on the LCD.
To continue a reset:
Press Enter.
To cancel a reset:
Press Escape.
Caution – Never press Reset while a tape cartridge is in a tape drive. If this
should happen, manually eject the cartridge.
The SPARCstorage Library features a security option that prevents users from
inadvertently changing important settings and operations. When security is
enabled, access to the following LCD activities is prevented:
•
Changing the control mode
Operating the SPARCstorage Library
1
1-7