Intel® SAS Expander Card Removal
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
3.
Remove the air duct (see
4.
Disconnect all the cables attached to the SAS expander card.
5.
Unscrew the three screws on the SAS expander card (see Letter A).
6.
Lift the SAS expander card from the chassis all the way out (see Letter B).
7.
Return the three screws to the threaded holes on the base of the chassis
8.
Reinstall the air duct (see
9.
Reinstall the system top cover (see
3.13 Intel® RAID Maintenance Free Backup Unit (RMFBU) and Mounting Bracket
Installation / Removal
This section provides instructions to install an RMFBU bracket and assembly in the system. Refer to the Intel®
Server M50CYP Family configuration Guide for available options.
Required Tools and Supplies
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
The RMFBU assembly has the following elements:
Latch
Supercap capacitor
RMFBU plastic case
The RMFBU bracket and assembly is installed in the same area inside the chassis as the SAS interposer card
(see
Section
3.11).
The three elements need to be assembled before attaching to the mounting bracket.