Image Format Control Item
GradationCompression
Mode
Related Topic:
Gradation
Compression Mode
GradationCompression
1stKneePoint
GradationCompression1stGain
GradationCompression
2ndKneePoint
GradationCompression2ndGain
TestPattern
ImageCompressionMode
Related Topic:
Image
Compression Mode (Xpress)
OverlayMode
Related Topic:
Overlay Mode
Setting
Default
Range
Value
0: Off
0: Off
1: On
-
50
-
0
-
100
-
0
-
0: Off
0: Off
0: Off
1: Lossless
-
0: Off
- 97 -
User Manual (Ver. Preliminary) - Setting List
Description
Enables the sensor's gradation compression function.
Set the first knee point of the sensor's gradation compression
function in percentage.
Setting Range (%): 0, 6.25, 12.5, 25, 50, 100
Max Value: 0 or the GradationCompression2ndKneePoint value,
whichever is smaller.
Set the first knee compression rate for the sensor's gradation
compression function in dB.
Setting Range (dB): 0, -6, -12, -18, -24, -30, -36, -42, -48, -54, -60,
-66
Set the second knee point of the sensor's gradation compression
function in percentage.
Setting Range (%): 6.25, 12.5, 25, 50, 100, 200, 400, 800
Min Value: GradationCompression1stKneePoint. However, when
GradationCompression1stKneePoint is set to 0, Min = 6.25
Set the second knee compression rate for the sensor's gradation
compression function in dB.
Setting Range (dB): 0, -6, -12, -18, -24, -30, -36, -42, -48, -54, -60,
-66
Select the test image.
0: Off (Default)
1: GreyHorizontalRamp
4: HorizontalColorBar (Color models only)
Enable/Disable the Lossless function.
Note: Monochrome models only.
You can check the target area by reducing the brightness of the
non-target area to 50%.
0: Off (Default)
1: MultiRoiAreaMode - Check the active area on MultiROI.
2: ALCAreaMode - Check the photometry area on ALC.
3: AWBAreaMode - Check the photometry area on AWB.