Step 5: Change the Camera Settings

This section explains how to change settings by describing the procedure for changing the output
format as an example.
Configure the Output Format
Configure the size, position, and pixel format of the images to be acquired. The factory settings are as
follows. Change the settings as necessary.
Factory default values (GOX-16205C-PGE)
ImageFormatControl
Note: You can specify the image acquisition area. For details, see
Example: Configure the Width of ImageFormatControl
1. By selecting the item of Width, you can change the value as shown below.
Note: Depending on the setting item, you need to change visibility. Please switch visibility
(Beginner / Expert / Guru) as necessary.
Item
Width
Height
OffsetX
OffsetY
PixelFormat
- 27 -
User Manual (Ver. Preliminary) - Preparation
Default Value
5328
3040
0
0
BayerRG8