Parameter
Value / Range:
Units / Interpretation:
Command Equivalent:

NS Disable Symbol Set Selection

This command prevents the <STX>y and y commands from changing the default
single-byte symbol set. When enabled, DPL Symbol Set commands are ignored.
Parameter:
Value / Range:
Units / Interpretation:
Command Equivalent:
Limitations
When enabled, the only way to change the current symbol set is with the <STX>KcAS
command.

OF Option Feedback Mode

This command configures the printer to output the status of the RFID or Scanner
option to the active port.
Parameter
Value / Range:
Units / Interpretation:
Command Equivalent:
Value
D
Rx
S
Response
Once enabled, the printer will report information about the results of the last label
printed. One response per label is returned to the host (this includes each voided and
DPL Command Reference
NR
Y, N
Y = Enabled, N = Disabled
N/A
NS
Y, N
Y = Enabled, N = Disabled
N/A
OF
D, Rx, S
See table below.
N/A
Option Feedback Mode Units / Interpretation
Disable
RFID Enable, where x is the response format:
A = ASCII
H = Hexadecimal
Scanner Enable