Stx Kb Backfeed Time Delay; Stx Kc Get Configuration - Honeywell E-Class Series User Manual

Table of Contents

Advertisement

 
c - Command 1. Reserved. Should be 0.
l
 
d - Command 2. Reserved. Should be 0.
l
 
ee...e - Data to be encoded on RFID tag (HF – the last used block will be null-pad-
l
ded, if necessary). UHF ASCII formats must be 8 or 12 characters; and, UHF Hexa-
decimal formats must be 16 or 24 character pairs.
Sample
<STX>KaW0000054455354[CR]
Result
The sample above writes the data "TEST" at block zero.

STX Kb Backfeed Time Delay

This command controls the time a printed label is allowed to remain "presented"
before being retracted to the start of print position.
Syntax
<STX>Kbnnn<CR>
Parameters
Where:
 
nnn - Seconds/10 (0 to 255)
l

STX KC Get Configuration

This command returns the configuration of the printer. The form of the returned data
is similar to that of a printed Configuration Label. This command should be parsed by
KEYWORDS, not character positions. Each line is terminated by a CR (0x0d) & LF
(0x0a).
Syntax
<STX>KC<CR>
Behavior
Responds with Printer Configuration and DPL configuration information.
Note: The format of the displayed information will vary with printer, model, firmware version,
and equipped options.
DPL Command Reference
36

Advertisement

Table of Contents
loading

Table of Contents