Value / Range:
Units / Interpretation:
Command Equivalent:

SA SOP Adjust

This command sets the start of print (SOP) location, relative to the top of form. See
STX O Set Start of Print (SOP) Position
The EX2 accepts this command for backward compatibility only, limited in range (28-
228).
Parameter
Value / Range:
Units / Interpretation:
Command Equivalent:

SC Scalable Cache

This command sets the number of 1K blocks allocated for the scalable font engine.
Available memory dependent upon model (see
Allocations).
Parameter
Value / Range:
Units / Interpretation:
Command Equivalent:

SE SOP Emulation

This command enables the <STX>O and <STX>f print positioning commands to allow
backward compatibility with label formats designed for other printers.
Parameter
Value / Range:
Units / Interpretation:
Command Equivalent:
118
1 - 255
Specified value multiplied by ten milliseconds.
N/A
for command details.
SA
0 – 255 (128 nominal)
N/A
<STX>O
Memory Module Identifiers and
SC
100 – 8192
Kbytes
N/A
SE
A, L, P, D
A = Allegro
L = Prodigy Plus
P = Prodigy
D = Disable
N/A