Command
FPn
FSn
Behavior:
Sample:
<STX>L
D11
FA+
FB+
1911S0102600040P018P018New DPL World
FI+
1911S0102000040P018P018New DPL World
FI-B-
1911S0101400040P018P018New DPL World
FB+
1911S0100800040P018P018New DPL World
FB+I+
1911S0100200040P018P018New DPL World
FB-
E
Note: Note that if all format commands after the first FB+ were deleted the entire label
would have been printed with bold scalable fonts. This is what is meant by a state
change. Once invoked, that command is in affect until turned off or the label format is
terminated with the "E" "s" or the "X" command.

G Place Data in Global Register

The "G" command saves the print data of a print format record in a global register
(temporary storage). This data may be retrieved and copied to another record in the
same label format using the special Label Formatting Command: <STX>S. Global
registers are named in the order received, beginning with Register A, ending at
Register Z, and incrementing with each instance of the G command use.
Syntax
G
Sample
<STX>L
121100000000000Testing
G
135
Units
Purpose
Specifies the vertical
point size of the following
Points
text relative to the
baseline.
Specifies the horizontal
point size of the following
Points
text relative to the
baseline.
Notes
 
 
DPL  Command Reference

Advertisement

Table of Contents
loading