The sample returns results from the last dot check for every element and its
resistance up to 1350 ohms [with out of range (bad or suspect) values indicates as
******], the number of dots tested, the total number of bad or suspect dots detected,
as well as the minimum, maximum, and average resistance and variance.
DOTCHECK RESULTS
DOTS TESTED GOOD 830 OF 832
DOT OHMS
0
1
2
.
.
.
142
143 *****
144 *****
145
.
.
.
830
831
832
TOTAL BAD DOTS:
MIN
921 1640 1125 719
Sample 3
<STX>KHB<CR>
The sample returns results from the last dot check for the number of elements tested,
the number of the bad or suspect dot(s), the total number of bad or suspect dots, as
well as the minimum, maximum, and average resistance and variance.
DOTCHECK RESULTS
DOTS TESTED GOOD 830 OF 832
BAD DOT LIST
143
144
DPL Command Reference
1148
1148
1140
1199
1050
1116
1116
1116
MAX AVG VAR
2
54