dd - 2 digits for day
l
 
yyyy - 4 digits for year
l
 
hh - 2 digits for hour in 24 hour format
l
 
MM - 2 digits for minutes
l
 
jjj - 3 digits for Julian date / constant
l
Sample
<STX>A1020319960855034
Result
Mon. Feb 3, 1996, 8:55AM, 034
Limitations
 
When set to 000, the Julian date is automatically calculated; otherwise, the Julian
l
date will print as entered, without daily increments. If factory defaults are restored,
the actual Julian date will also be restored.
 
Printers without the Real Time Clock option lose the set time/date when power is
l
removed.
 
Response format is variable. See
l

STX a Enable Feedback Characters

Enables the feedback of ASCII hex data characters to be returned from the printer
following specific events during data parsing and printing. The default value is "OFF".
Syntax
<STX>a
Behavior
Printer response:
Event
Invalid character
Label printed
End of batch
See

STX B Get Printer Time and Date Information

This command instructs the printer to retrieve its internal time and date information.
DPL Command Reference
Reset Codes
for error code information.
STX T Print Time and
Return Characters
0x07 ( BEL )
0x1E ( RS )
0x1F ( US )
Date.