CF Column Adjust Fine Tune
This command fine-tunes the Column Offset setting by shifting both the horizontal
start of print position and the Label Width termination point to the right in dots to
compensate for slight mechanical differences sometimes evident when multiple
printers share label formats.
Parameter:
Value / Range:
Units / Interpretation:
Command Equivalent:
CH Communicated Heat Commands
This command causes the printer to ignore DPL Heat commands. Ignore by setting
value to N. Process by setting value to Y (default). When set to ignore Heat commands
values are controlled via the menu setting.
Parameter:
Value / Range:
Units / Interpretation:
Command Equivalent:
CL Continuous Label Length
See <STX>c for command details.
Parameter:
Value / Range:
Units / Interpretation:
Command Equivalent:
CO Column Offset
See Cnnnn for command details.
Parameter:
Value / Range:
Units / Interpretation:
Command Equivalent:
80
CF
+ / – dots
Resolution specific (see
Maximum Width & Record Column
N/A
CH
Y, N or 1, 0
Y = Enabled, N = Disabled; or 1 = Enabled, 0 = Disabled
N/A
CL
0 - 9999
1/100 in. or 1/10 mm
<STX>c
CO
0 - 9999
1/100 in. or 1/10 mm;
Cnnnn
Print Resolutions and
Values).