B Barcode Magnification

This command provides a mechanism to specify barcodes greater than 36 dots (0 - 9,
A - Z in the field record). The value is reset to 1 at the start of every label and stays
active for the entire label or set to a new value.
Syntax
Bnn
Parameters
Where:
 
nn -  Is a two digit decimal number indicating the magnification value.
l
Sample
<STX>L
D11
B01
1a9305000100030ABCD
B03
1a3105000700030ABCD
Q0001
E
Result
The sample above instructs the printer to print two barcodes, each 9 dots by 3 dots.

C Set Column Offset Amount

This command allows horizontal adjustment of the point where printing begins. The
printer is instructed to print label formats nnnn units to the right of the position that
the format specifies. This feature is useful when a single format is to be printed on
labels containing preprinted information.
Syntax
Cnnnn
Parameters
Where:
 
nnnn - Is a four-digit number for the column offset, inches/100 or mm/10. The
l
default is 0.
Sample
<STX>L
C0050
131