Where:
Field
Valid Inputs
a
1, 2, 3, and 4
W
W
b[b]
c, 1c
c
1 to 9, A to Z, and a to z
d
1 to 9, A to Z, and a to z
eee
000 to 999
ffff
0000 to 9999
gggg 0000 to 9999
hhh
200
i
0
10, 12, 14, 16, 18, 20, 22, 24, 26,
jjj
32, 36, 40, 44, 48, 52, 64, 72, 80,
88, 96, 104, 120, 132, 144
10, 12, 14, 16, 18, 20, 22, 24, 26,
kkk
32, 36, 40, 44, 48, 52, 64, 72, 80,
88, 96, 104, 120, 132, 144
8-bit data, followed by a
ll...l
termination character.
Sample
<STX>L
D11<CR>
1W1c44000010001002000000000DATAMAX<CR>
121100000000100Barcode W1c<CR>
E
Result
Prints a W1c DataMatrix barcode.
212
Meaning
Rotation
Fixed value, extended barcode set
Selects the DataMatrix barcode - the two differing values
have no other significance.
Module size horizontal multiplier
Module size vertical multiplier
No effect; Must be numeric
Label position, row
Label position, column
ECC 200 uses Reed-Solomon error correction.
Fixed value, not used
A 3-digit even number (or 000) of rows requested.
000 causes rows to be automatically determined. The
symbol will be sized to a square if the rows and columns do
not match by taking the larger of the two values.
A 3-digit even number (or 000) of columns requested.
000 causes columns to be automatically determined. The
symbol will be sized to a square if the rows and columns do
not match by taking the larger of the two values.
Data to be encoded.