W1f / W1F Aztec Barcode

Label format barcode ID for printing an Aztec barcode in variable (W1f) and fixed
length (W1F) modes.
Variable Length (W1f): This two dimensional barcode holds a large amount of data in
a small area and can provide a high level of error checking.
Specified Length (W1F): With a string four-digit length specifier, values 0x00 through
0xFF to be included within the data strings without conflicting with the DPL format
record terminators.
Syntax
a W1 b c d eee ffff gggg [hhhh] i jjj kk...k
Parameters
Where:
Field
Valid Inputs
a
1, 2, 3, and 4 Rotation
W1
W1
b
f and F
1 to 9, A to Z,
c
and a to z
1 to 9, A to Z,
d
and a to z
eee
000
0000 to
ffff
9999
0000 to
gggg
9999
0000 to
[hhhh]
9999
i
0, 1
220
Meaning
Fixed value, extended barcode set
Lowercase selects the Aztec barcode, variable length.
Uppercase selects the Aztec barcode with a Byte Count Specifier.
Module size horizontal multiplier, 0 = default size. The c/d module size
parameters should be equal to produce a square symbol. When the label
command (Dwh) is used to generate larger text, then c and d may be used to
compensate and ensure a square symbol.
Module size vertical multiplier, 0 = default size (See explanation for "c", above.)
No Effect
Label position, row
Label position, column
Optional string length specifier. Field termination is set by this byte count. This
decimal value includes all of the data following this byte count field, but does
not include itself.
Extended Channel Interpretation (ECI) mode; 0 = Disabled, 1 = Enabled