If the operator switch is in a non-functional state, the operator may opt to use the touch screen activity monitor.
The activity monitor uses input on the field computer touch screen to reset a 7 minute timer. If the timer does
expire, the system will disable automated steering until the operator touches the screen and reengages the
steering system.
Current Voltage. Displays the current switch voltage. This display may be useful to adjust the upper and lower
voltage limits if necessary.
Lower Limit. Use this setting to set the lower voltage limit. This is the voltage at which the switch will toggle when
the operator is seated or the Activity Monitor is enabled.
Upper Limit (Double Pole Switch Only). Use this setting to adjust the upper voltage limit. Set the upper limit so
that the current voltage reading remains below the upper limit while the operator is seated. If the presence switch
voltage exceeds the upper limit, the presence switch will disengage steering.
Status. Displays the operator presence switch status. Toggle the presence switch (e.g. stand or sit in the operator
seat) and confirm that the status indicates the switch is on when the operator is seated.
If the status does not change, but the current voltage changes, adjust the upper and lower limit settings as
necessary.
NOTE:
Review Chapter 10, Diagnostics and Troubleshooting, for information on the status displayed in this
area.
016-4010-001 Rev. J
STEERING SETUP
41