A.1 00 (0x00) Reading the Name of a Module
Description
This sub-function code is used to read the name of a module.
Request
Byte
Description
00
Address
01
Function Code
Sub-Function
02
Code
Response
Byte
Description
00
Address
01
Function Code
Sub-function
02
Code
03~06 Module Name
Error Response
Byte
Description
00
Address
01
Function Code
02
Exception Code
ICP DAS, ZT-2017 and ZT-2017C AI Series User Manual, Version 1.0.1
Copyright © 2012 by ICP DAS Co., Ltd. All Rights Reserved.
Length Value
1
1 to 247
1
0x46
1
0x00
Length Value
1
1 to 247
1
0x46
1
0x00
0x54 0x20 0x17 0x00(ZT-2017)
4
0x54 0x20 0x17 0x13(ZT-2017C)
Length Value
1
1 to 247
1
0xC6
Refer to the Modbus standard for more
1
details