Chapter 5. Power
This chapter describes the power specifications for the Jetson AGX Xavier Series module.
!
CAUTION: Jetson AGX Xavier is not hot-pluggable. Before installing or removing the module, the
main power supply (to SYS_VIN_HV and SYS_VIN_MV pins) must be disconnected and the power
rails allowed to discharge to <0.6V.
Note: Additional power, system, and thermal signals related to safety can be found in Section
15.5 "Safety MCU JAXi Only."
Table 5-1.
Power, System, and Thermal Pin Descriptions
Pin #
Module Pin
SoC Signal
Name
Note 1
SYS_VIN_HV
Note 2
SYS_VIN_MV
L53
VCC_RTC
L62
CARRIER_
POWER_ON
L10
FORCE_
SOC_GPIO00
RECOVERY_N
L54
MODULE_
POWER_ON
L58
PERIPHERAL_
−
RESET_N
L61
POWER_BTN_N
POWER_ON
Jetson AGX Xavier Series Product
Usage/Description
–
System Voltage Input - High
–
System Voltage Input - Medium
−
Real-Time-Clock. Optionally used to provide
back-up power for RTC. Connects to Lithium Cell
or super capacitor on carrier board. PMIC is
supply when charging cap/cell. Super cap or coin
cell is source when system is disconnected from
power.
−
Carrier Power On. Used as part of the power up
sequence. When asserted, it is safe for the carrier
board to power up. 100kΩ pull-up to 3.3V on
module.
Force Recovery strap pin. Held low when
SYS_RESET_N goes inactive (power-on or reset
button press) to enter force recovery mode.
−
Module Power On. Signal to module to start
power-on sequence. Driven by power button
supervisor if implemented. Open-drain if power
button supervisor MCU not implemented. If non-
MCU circuit used, signal should have a 100kΩ
pull-up to VDD_5V.
Peripheral Reset. Driven from carrier board to
force reset of SoC and eMMC and QSPI (not PMIC).
100kΩ pull-up to 1.8V on the module.
Power Button. Used to initiate a system power-on
and to enter/exit SC7. 3.3V to 1.8V level shifter on
the module.
Usage on NVIDIA
Direction
Carrier Board
Main High Voltage DC
Input
Input
Main Medium Voltage
Input
DC Input
Battery back-up using
Bidir
Super-capacitor
Used to enable 1.8V/3.3V
Output
regulators and routed to
power button supervisor
and discharge circuits.
Routed to Force
Input
Recovery button and
automation header.
Generated by power
Input
button supervisor or
non-MCU power-on
circuit.
Unused
Input
Generated by power
Input
button supervisor.
DG-09840-001_v2.5 | 16
Pin Type
Power: 9V to 20V
Power: 5.0V
Power: Input
Voltage Range:
1.65V-5.5V
Output Voltage
Range:
See Note 4
na
CMOS – 1.8V
5.0V Open-Drain
(Non-MCU case).
CMOS – 3.3V
(Power Button
MCU case)
CMOS – 1.8V