of each phase for the single unit is L1/L2:17A, L3:0A, and different model of
rated AC current is different, the detailed specification refer to the technical
specification.
Connecting the Power Cord
Suggestions for phase assignment:
When connecting the instrument which rated power less than 10kW to AC
distribution box, please take care for balanced current distribution on three
phases. For single unit, it requires two or three phases of a three-phase AC
distribution box (the rated AC current on L3 is 0, so, it can be connected or
not). In case multiple units are connected to the same main AC distribution
box. It is recommended to follow the suggestion connection diagram as
below.
When connecting the instrument which rated power with 10kW≤ Power<
15kW to AC distribution box, For single unit, it requires three phases of a
three-phase AC distribution box. In case multiple units are connected to the
same main AC distribution box. It is recommended to follow the suggestion
connection diagram as below.