Working Temperature
Dimension ( mm)
Weight( net)
Note: 1. The instrument needs to be customized under other AC input voltage ranges. For mod-
els equipped with an emergency stop module (including AC contactor), the AC input voltage
range can only be: 342V~528V

6.1.6 2250V

6.1.6.1 IT6018C-2250-25

Rated value ( 0 ℃-50 ℃)
Line Regulation
±(%of Output+Offset)
Load Regulation
±(%of Output+Offset)
Setup Resolution
Read Back Resolution
Setup Accuracy (within 12
months, 25℃ ±5℃) ±(%
ofOutput+Offset)
Parameter
Parameter
Output Voltage
Output Current
Output Power
Output Resistance
Voltage
Current
Voltage
Current
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Copyright © Itech Electronic Co., Ltd.
0~50℃
483mm(W)*801.61mm(D)*151.3mm(H)
40KG
Technical Specification
IT6018C-1500-40
IT6018C-2250-25
0~2250V
-25~25A
-18~18kW
0~1Ω
≤0.01%FS
≤0.05%FS
≤0.02%FS
≤0.05%FS
0.1V
0.001A
0.001kW
0.001Ω
0.1V
0.001A
0.001kW
0.001Ω
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS