3. After the menu items are set, press [Enter] again to save the modified
contents.
The description of the menu items is shown in the table below.
Beep
Set the beeper state.
On
Off
Set the power-on state.
PowerOn
Reset
Last
Last+Off
Sense
Set the sense function state.
Off
On
ListTrig Source
Set the trigger method for the List files running.
Immediate Trigger immediately
Manual
Bus
External
DLogTrig Source
Set the trigger method for the data logging.
Immediate Trigger immediately
Manual
Bus
Voltage
Current
External
I/O
Set the communication information between instrument and PC.
USB
You can press [Esc] to return to the previous menu.
Turn the beeper on.
Turn the beeper off.
When the instrument is powered on, the instrument will in-
itialize some settings and [On/Off] state.
When the instrument is powered on, the instrument will re-
main the same settings and [On/Off] state as last time
you turned off the instrument.
When the instrument is powered on, the instrument will re-
main the same settings as last time you turned off the in-
strument, but the [On/Off] is OFF state.
Turn the sense function off.
Turn the sense function on.
Manual trigger
Bus trigger
External trigger
Manual trigger
Bus trigger
Voltage trigger
Current trigger
External trigger
USB communication interface
USB-TMC protocol
TMC
Copyright © Itech Electronic Co., Ltd.