Christie CineLife+ 4 Series Technical Reference page 20

Serial commands
Hide thumbs Also See for CineLife+ 4 Series:
Table of Contents

Advertisement

Parameters
Access level: Operator
Power level (minimum): Power Up
Commands
Command
LVO?
LVO <position> <1 | -1>
LVO+MOVR <step>
LVO+STOP
LVO+STRT <1 | -1>
Examples
Return current motor position along the vertical axis and direction:
(LVO?)
Move lens to position 500 along the vertical axis with a positive approach:
(LVO 500 1)
Move lens to position 500 along the vertical axis with a negative approach:
(LVO 500 -1)
Move the motor 100 steps in a negative direction:
(LVO+MOVR -100)
Move the motor 200 steps in a positive direction:
(LVO+MOVR 200)
Stop the motor:
(LVO+STOP)
Start the motor moving in a positive direction:
(LVO+STRT 1)
CineLife+ Technical Reference–Serial Commands
020-103075-05 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Description
Returns the current motor position along the
vertical axis and direction. (Read-only)
Moves the lens mount to a specified vertical
position with a specified direction.
Moves the motor a given number of steps based
on the current location.
Stops the motor.
Starts the motor moving in a specified direction.
CineLife+
serial commands
Values
position = Numeric value
-1 = Negative approach
1 = Positive approach
step = Numeric value
-1 = Negative approach
1 = Positive approach
20