Download Print this page

Sharp UP-5900 Service Manual page 81

Advertisement

22-2. TOUCH PANEL CONTROL
UART5 included in PSC2 as Mega Macro Function is used. The I/O address for this interface is PSC2 + (810h-817h) = 990h-997h.
Command (CPU->Controller)
Command
RESET
Controller initialization
COLD-RST
Coordinate initialization
STOP
Coordinate data send inhibit
START
Coordinate data send resume
CAL-IN
Correction start
CAL-OUT
Correction complete
CAL-SET
Previous data are set to Correction point.
CANSEL
Correction interrupt
REPORT
Controller state inquiry
DIAG
Self diag execution
SET-TIME
Timer setup after Pen Up
SET-RATE
Sampling interval setup
WRITE
Write to E2PROM
READ
Read from E2PROM
Reserve
Reserve
CALTRN
Transmits the correction coefficient to CPU.
CALRCV
Transmits the correction coefficient to this controller.
DUMY
Dummy Data for Sleep Cancel
— Pen Down —
22-3. TOUCH PANEL
Film side
resistance
membrane
Glass side
resistance
membrane
:
Parts on the top of glass
Pin# Signal
1
U
A/D Converter(Y-axis start point electrode voltage monitor)
2
R
A/D Converter (X-axis start point electrode voltage monitor)
3
A
Y-axis detection power
4
L
A/D Converter (X-axis end point electrode voltage monitor)
5
B
X-axis detection power
6
D
A/D Converter (Y-axis end point electrode voltage monitor)
7
C
A/D Converter (Touch coordinate detection)
Function
U
R
A
L
B
D
C
:
Electrode
Memo
UP-5900VS CIRCUIT DESCRIPTION
Code
Ope-code
80h
0
81h
0
82h
0
83h
0
84h
9
85h
4
86h
0
87h
0
88h
0
89h
1
8Ah
1
8Bh
1
8Ch
3
8Dh
1
8Eh
|
8Fh
|
E0h
1
E1h
170
FFh
0
CN
1
2
3
4
5
6
7
5 – 51
Response
End Code
Coordinate Code Notification Data
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
o
u
u
o
u
u
u
u
u
u
u
u
o
u
u
u
u
o
u
o
u

Advertisement

loading