stp-callproc

stp-callproc
The stp-callproc command stops further call processing by immediately terminating the handling of new
call requests.
Syntax Description
timeout
T
Examples
In the following example, the command stops further call processing by immediately terminating the
handling of new call requests:
gw mml> stp-callproc
H323 Signaling Interface Thu Dec 14 16:27:07 2000
M SUCC
Stopped accepting new calls. Existing calls will be released in 5 seconds.
Stopping Call Processing.

stp-softw

The stp-softw command stops the call processing application. This command causes the Cisco HSI to
terminate.
Syntax Description
confirm
Examples
In the following example, the command stops the call processing application:
gw mml> stp-softw
H323 Signaling Interface Thu Dec 14 16:27:36 2000
M SUCC
There are no active calls.
Application is now stopping
Cisco H.323 Signaling Interface User Guide
A-40
stp-callproc[:timeout=T]
If no timeout period is provided, existing calls are released immediately. If
a timeout period is provided, existing calls are released after the specified
amount of time has elapsed. When all calls have been released, a
notification message is sent to the craft terminal.
T is in seconds.
stp-softw[:confirm]
If there are active calls, a notification is sent to the craft. In order for the
command to take effect, it must be reentered with the confirm parameter.