2.7. Standards and Certifications

The COMe-cEL6 complies with the following standards and certificates. If modified, the prerequisites for specific
approvals may no longer apply. For more information, contact Kontron Support.

Table 13: Standards and Certifications

EMC
Emission
EN 55032 Class B
Immunity
IEC / EN 61000-6-2
Safety
Europe
EN 62368-1
USA & Canada
UL 62368-1/CSA 62368-1
(Component Recognition)
Environment
Shock
IEC / EN 60068-2-27
Vibration
IEC / EN 60068-2-6
RoHS II
Directive 2011/65/EU incl.
2015/863/EU
2.7.1.

MTBF

The MTBF (Mean Time Before Failure) values were calculated using a combination of the manufacturer's test data, (if
available) and the Telcordia (Bellcore) issue 2 calculations for the remaining parts.
The Telcordia calculation used is "Method 1 Case 3" in a ground benign, controlled environment. This particular
method takes into account varying temperature and stress data and the system is assumed to have not been burned-
in. Other environmental stresses (such as extreme altitude, vibration, salt-water exposure) lower MTBF values.

Table 14: MTBF Values

COMe-cEL6 E2 x6425RE 16S 2.5G
System MTBF (hour) = 443061 hours @ 40°C
Reliability report article number: 36034-0016-R2-5EVL
COMe-cEL6 J6426
System MTBF (hour) = 587426 hours @ 40°C
Reliability report article number: 36033-0000-J2-4
COMe-cEL6 E2 x6425RE
System MTBF (hour) = 587426 hours @ 40°C
Reliability report article number: 36034-0000-R2-4
www.kontron.com
Electromagnetic compatibility of multimedia equipment -
Emission requirements
Electromagnetic compatibility (EMC) Part 6-2: Generic
standards - Immunity standard for industrial environments
Safety for audio/video and information technology equipment
Recognized by Underwriters Laboratories Inc. Representative
samples of this component have been evaluated by UL and
meet applicable UL requirements.
UL listings:
AZOT2.E147705
AZOT8.E147705
Non-operating shock test
(half-sinusoidal, 11 ms, 15 g)
Non-operating vibration
(sinusoidal, 10 Hz – 2000 Hz, +/- 0.15 mm, 2 g)
Restriction of Hazardous Substances in electrical and
Electronic Equipment (RoHS)