Table 9: Single Power Supply Mode Settings - Kontron COMe-cEL6 User Manual

Table of Contents

Advertisement

2.4.3.2. Single Power Supply Mode
To start the module in single power supply mode, connect VCC power and open PWR_OK at the high level. VCC can be
8.5 V to 20 V. To power on the module from S5 state, press the power button or reconnect VCC.
Suspend/Standby states are not supported in single power supply mode.

Table 9: Single Power Supply Mode Settings

State
PWRBTN#
G3
[1]
0V/x
S5
high
S5 → S0
PWRBTN Event
G3 → S0
high
[1]
Defines that there is no difference if connected or open.
All ground pins must be connected to the carrier board's ground plane.
www.kontron.com
PWR_OK
V5_Standby
[1]
[1]
0V/x
0V/x
open / high
open
open / high
open
open / high
open
COMe-cEL6 - User Guide, Rev.1.2
VCC
[1]
0V/x
VCC
reconnecting VCC
connecting VCC
// 29