CFG_AUTO_DETECT
Specify whether to automatically detect the UPS or PSU configuration.
1: TRUE (enable)
0: FALSE (disable)
The default setting is "0" (disable).
When this item is set to "1" (enabled), the values specified in CFG_NUM_OF_UPSES
and CFG_NUM_OF_POWERSUPPLIES are made invalid.
Notes
When EM card performs UPS management, the EM card must know the IP address of UPS. To
distribute an IP address through the DHCP server of EM card, set to "Enable" for DHCP feature of
EM management. If the IP address directly assigned to UPS is used, the DHCP feature may be
enabled or disabled.
Maximum power consumption management is not available when using automatic CPU blade boot
after UPS power recovery.
-
-
71