NEC N8405-019 User Manual page 103

Em card
Hide thumbs Also See for N8405-019:
Table of Contents

Advertisement

apply
Outline
Apply the settings of configuration file to the EM card.
Syntax
apply
Parameter
None
Details
Apply the settings of configuration file (rw_poem.conf) to the EM card. When two EM
cards are installed, the settings for active EM card are applied to both cards. This
command can be executed only in the active EM card.
Notes
Reboots the EM firmware when the configuration file is applied. When two EM cards are
installed, both EM firmwares are rebooted simultaneously.
The bridge and SNMP functions are stopped during rebooting. Accordingly, the CPU
blade and switch module are temporarily disconnected from LAN. In addition, monitoring
the system by NEC ESMPRO or others is temporarily disabled. If a timeout error occurs,
provide these connections again after the active EM has rebooted.
When two EM cards are installed, the standby EM must also be operating normally. If the
standby EM is being activated or failed, "apply" command cannot be executed.
Wait until the standby EM becomes ready, then execute this command.
If the standby EM is failed, remove it. Then, execute this command.
Examples
<When succeeded>
------------------------------------------------------------------------
$ apply
Restarting system.
------------------------------------------------------------------------
<When failed>
------------------------------------------------------------------------
$ apply
WARNING: Standby EM is inserted, but is not ready to apply the
configuration.
Please retry after a while.
------------------------------------------------------------------------
-
83
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

N8405-019n

Table of Contents