Related Products And Instrument Accessories; Appendix; Updating Firmware - Promega Maxwell 16 Forensic Technical Manual

Table of Contents

Advertisement

10.C. Related Products and Instrument Accessories
Product
Maxwell
®
16 LEV Cartridge Rack (for use with LEV configuration)
Maxwell
16 LEV Magnet (for use with LEV configuration)
®
Maxwell
16 LEV High Strength Magnetic Rod Assembly and Plunger Bar Adaptor
®
(for use with LEV configuration)
Maxwell
16 Cartridge Rack (for use with SEV configuration)
®
Maxwell
16 Magnetic Elution Rack (for use with SEV configuration)
®
Maxwell
16 LEV Magnet
®
Bar Code Reader for Maxwell
Thermal, Serial Printer and Cable, Universal Power
LEV Plungers
SEV Plungers
LEV Elution Tubes
SEV Elution Tubes
UV Bulb

11. Appendix

11.A. Updating Firmware
As Promega provides new purification kits, new versions of firmware may be required. The firmware version installed
on your instrument can be verified by turning the machine off, then on again. The initial screen will display the version
number of the firmware loaded on the instrument. Please note the firmware version currently installed on your
instrument before contacting Promega or your local Promega representative for new firmware.
Firmware is updated using an SD card reader in the Maxwell
firmware as a main.bin file from the Promega web site onto a computer. Place the SD card in the computer's SD card
slot, and download the updated firmware to the SD card. If you do not have an SD card reader on your computer, use
the enclosed SD card reader to download the updated firmware to the SD card through a USB port on your computer.
Place the SD card containing the firmware into the SD slot on the instrument; make sure the instrument door is closed,
and turn the instrument off and on. The instrument will install the firmware, the Maxwell
screen will indicate that the firmware is being updated, and the instrument will go through the diagnostic checks.
During the diagnostic checks, the instrument will display the new firmware version. When installation is complete, the
Home screen will open. If the firmware was loaded successfully, the main.bin file will be deleted from the SD card.
48
Promega Corporation · 2800 Woods Hollow Road · Madison, WI 53711-5399 USA · Toll Free in USA 800-356-9526 · 608-274-4330 · Fax 608-277-2516
TM321 · Revised 4/15
16
®
16 Forensic Instrument SD slot. Download the updated
®
Size
Cat.#
1 each
AS1251
1 each
AS1261
1 each
SP1070
1 each
AS1201
1 each
AS1202
1 each
AS1261
1 each
AS3200
1 each
E2821
50 each
AS6151
50 each
AS5201
50 each
AS6201
50 each
AS5101
1 each
SP1080
16 Forensic Instrument
®
www.promega.com

Advertisement

Table of Contents
loading

Table of Contents