4. OPERATION

4.3.2 Manual pulse generator operation

(1) Setting
Set the input signal and parameters as follows according to the purpose of use. In this case, the point
table No. selection 1 to 4 signals (DI0 to DI3) are invalid:
Manual operation mode selection
Manual pulse generator
multiplication
Servo motor rotation direction
(2) Servo motor rotation direction
Parameter No. 1 Setting
Forward rotation
(3) Manual pulse generator multiplication
(a) Using the parameter for setting
Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No. 1 Setting
Downloaded from
ManualsNet.com
Item
Automatic/manual selection (MD0)
Parameter No.1
Parameter No.1
Manual pulse generator: Forward rotation
0
CCW rotation
1
CW rotation
CCW
CW
Multiplication Ratio of Servo Motor Rotation to Manual
0
1
2
search engine
Setting Method
Servo Motor Rotation Direction
Manual pulse generator: Reverse rotation
Pulse Generator Rotation
1 time
10 times
100 times
4 - 19
Description
Open MD0-SG (OFF).
Set the multiplication ratio of servo
motor rotation to the pulses generated
by the manual pulse generator.
For more information, refer to (3) in this
section.
Refer to (2) in this section.
CW rotation
CCW rotation
Moving Distance
1[ m]
10[ m]
100[ m]