2) Incremental value command system

Parameter No.1 Setting
(c) Feed length multiplication (parameter No.1)
Set the feed length multiplication factor (STM) of position data.
1) Absolute value command
Parameter No.1 Setting
2) Incremental value command system
Parameter No.1 Setting
Downloaded from
ManualsNet.com
Forward Rotation Start (ST1) ON
0
CCW rotation (address incremented)
1
CW rotation (address incremented)
ST1:ON
CCW
CW
ST2:ON
Parameter No. 1
0
Position Data Input Range [mm]
0
999.999 to 999.999
1
9999.99 to 9999.99
2
99999.9 to 99999.9
3
999999 to 999999
Position Data Input Range [mm]
0
0 to 999.999
1
0 to 9999.99
2
0 to 99999.9
3
0 to 999999
search engine
Servo Motor Rotation Direction
Reverse Rotation Start (ST2) ON
CW rotation (address decremented)
CCW rotation (address decremented)
ST2:ON
CCW
CW
ST1:ON
Parameter No. 1