4. OPERATION

4.3.2 Manual pulse generator operation

(1) Setting
Set the input signal and parameters as follows according to the purpose of use. In this case, the
program No. selection 1 to 4 (DI0 to DI3) are invalid:
Item
Manual operation mode selection
Manual pulse generator
multiplication
Servo motor rotation direction
Jog speed
Acceleration/deceleration time
constant
(2) Servo motor rotation direction
Parameter No. 1 setting
0
1
Forward rotation
(3) Manual pulse generator multiplication
(a) Using the parameter for setting
Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No. 1 setting
0
1
2
Setting method
Automatic/manual selection (MD0)
Parameter No.1
Parameter No.1
Parameter No.13
Parameter No.40
Manual pulse generator: forward rotation
CCW rotation
CW rotation
CCW
CW
Multiplication ratio of servo motor rotation to manual
pulse generator rotation
10 times
100 times
4 - 29
Servo motor rotation direction
Manual pulse generator: reverse rotation
1 time
Description
MD0 is switched off.
Set the multiplication ratio of servo
motor rotation to the pulses generated
by the manual pulse generator.
For more information, refer to (3) in this
section.
Refer to (2) in this section.
Set the speed of the servo motor.
Use the acceleration/deceleration time
constants.
CW rotation
CCW rotation
Moving distance
1[ m]
10[ m]
100[ m]