3. SIGNALS AND WIRING

3.7.2 Terminals

The positions and signal arrangements of the terminal blocks change with the capacity of the servo
amplifier. Refer to Section 12.2.1.
Symbol
L
, L
, L
1
2
3
U, V, W
L
, L
11
21
P, C, D
N
Downloaded from
ManualsNet.com
Signal
Main circuit power supply
Servo motor output
Control circuit power supply
Regenerative brake option
Protective earth (PE)
search engine
Supply L
, L
and L
with the following power.
1
2
3
For a single-phase 230VAC power supply, connect the power supply to L
L
and keep L
open:
2
3
Servo amplifier
Power supply
3-phase 200 to 230VAC,
50/60Hz
Single-phase 230VAC,
50/60Hz
Cannot be used for combination with the servo motor HC-SF52 53.
Connect to the servo motor power supply terminals (U, V, W). During power-
on, do not open or close the motor power line. Otherwise, a malfunction or
faulty may occur.
Control circuit power input terminals
Supply L
and L
with single-phase 200-230VAC, 50/60Hz power.
11
21
C and D (Servo amplifier built-in regenerative brake version) are factory-
connected.
When using the regenerative brake option, always remove wiring from across
P-D and connect the regenerative brake option across P-C.
Do not connect.
Connect this terminal to the protective earth (PE) terminals of the servo
motor and control box for grounding.
3 - 22