6. SERVO CONFIGURATION SOFTWARE

6.6 Device setting

Click "Parameters" on the menu bar and click "I/O Devices" on the menu.
When the above choices are made, the following window appears:
(1) Function assignment batch-read ( a) )
Click the "Read All" button to read and display from the servo amplifier the pins which have been
assigned functions.
(2) Function assignment batch-write ( b) )
Click the "Write All" button to write to the servo amplifier the pins which have been assigned functions.
Downloaded from
ManualsNet.com
POINT
When using the device setting, preset "000E" in parameter No.19.
c)
e)