5. PARAMETERS
Class No. Symbol
18
*DMD Status display selection, alarm history clear
19
*BLK
Downloaded from
ManualsNet.com
Name and Function
Used to select the status display shown at power-on and choose
alarm history clear.
0
Status display on servo amplifier
display at power-on
0: Servo motor speed (initial value)
1: Regenerative load ratio
2: Effective load ratio
3: Peak load ratio
4: Within one-revolution position
5: ABS count
6: Load inertia moment
Status display of MR-DP60
0: Current position (initial value)
1: Command position
2: Command remaining distance
3: Point table No.
4: Cumulative feedback pulses
5: Servo motor speed
6: Droop pulses
7: Override
8: Torque limit voltage
9: Regenerative load ratio
A: Effective load ratio
B: Peak load ratio
C: Within one-revolution position
D: ABS counter
E: Load inertia moment
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleared)
When alarm history clear is made valid, the
alarm history is cleared at next power-on.
After the alarm history is cleared, the setting
is automatically made invalid (reset to 0).
Parameter write inhibit
Used to select the reference and write ranges of the parameters.
Operation can be performed for the parameters marked
Set Value
Operation
Parameters
0000
Reference
(initial
Write
value)
Reference
No.19 only
000A
Write
No.19 only
Reference
000B
Write
Reference
000C
Write
Reference
(Note)
000E
Write
Note: Set this parameter when making device setting using the
Servo Configuration Software.
search engine
Basic
Expansion
Expansion
Parameters
Parameters
No.0 to 19
No.20 to 53
No.54 to 66
5 - 8
Initial
Setting
Unit
Value
Range
0000
Refer to
Name
and
function
column.
0000
Refer to
Name
.
and
function
column.
Reference
Section
7.2
Section
7.2
Section
5.2.6
Section
5.1.1