Write Commands - Mitsubishi Electric MELSERVO-J2 Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

8. COMMUNICATION FUNCTIONS

8.11.2 Write commands

(1) Status display (Command [8][1])
Command
[8][1]
(2) Parameter (Command [8][4])
Command
[8][4]
(3) External I/O signal (Command [9][2])
Command
[9][2]
(4) Alarm history (Command [8][2])
Command
[8][2]
(5) Current alarm (Command [8][2])
Command
[8][2]
Downloaded from
ManualsNet.com
Data No.
[0][0]
Status display data clear
Data No.
Each parameter write
[0][0] to
Decimal number of data No. corresponds to the
[3][5]
parameter number.
Data No.
Communication input device signal
[6][0]
Data No.
[2][0]
Alarm history clear
Data No.
[0][0]
Alarm reset
search engine
Description
Description
Description
Description
Description
8 - 13
Setting Range
Frame Length
1EA5
Setting Range
Frame Length
Depends on the
parameter.
Setting Range
Frame Length
Refer to Section
8.12.5
Setting Range
Frame Length
1EA5
Setting Range
Frame Length
1EA5
4
8
8
4
4