Application Flag - Pepperl+Fuchs IMUF99 B20 Series Manual

Inertial measurement unit
Table of Contents

Advertisement

Inertial Measurement Unit IMUF99*B20
Commissioning
5.8

Application Flag

Independent limits can be set for the X, Y and Z axes of the acceleration, rotation rate and
angle measurement axes. If these limits are exceeded, this is indicated in the switching status
of the Application Flags (AF). The parameters 0x69 to 0x8C are used to set the application
flags (AF).
If the switching points are exceeded or dropped below, this can be recognized directly by the
status of the application flag (AF) in byte 7 of
PDO 0 (MappingID 9) for acceleration
PDO 1 (MappingID 10) for yaw rate
and PD0 5 (MappingID 11) for angle
The following table shows how the AF status can be interpreted based on the PDO content for
each measured value.
Content Byte 7
Mapping ID 9,
10 ,11
HEX
00
01
02
03
04
05
06
07
Table 5.10
22
Content Byte 7
z-Application
Mapping ID 9,
Flag
10 ,11
Binary
000
Not active
001
Not active
010
Not active
011
Not active
100
Active
101
Active
110
Active
111
Active
y-Application
x-Application
Flag
Flag
Not active
Not active
Not active
Active
Active
Not active
Active
Active
Not active
Not active
Not active
Active
Active
Not active
Active
Active

Advertisement