Inertial Measurement Unit IMUF99*B20
Product Description
2.2
LED displays
The IMU360D-F99 has three LED indicators that allow rapid visual monitoring.
•
The green power LED indicates the state of the power supply
•
The yellow run LED indicates the bus and sensor status
•
The red err LED indicates an error
LED
Green: power
Yellow: run
Red: err
Table 2.1
Possible sources of error causes:
•
CAN master is not initialized
•
Baud rate is wrong
•
CAN-high and CAN-low channel are interchanged
2.3
Accessories
Various accessories are available. See datasheet or relevant product page on the Internet
www.pepperl-fuchs.com.
State
Description
On
Voltage ok
Off
No power or sensor defect
On
Operational mode
Blinking slowly
Parameter mode user
Off
Error see red LED "err"
On
•
•
•
Blinking slowly
Claiming conflict, Null address (254)
Flashing
CAN err warning level
Off
No error
Address claiming (max 250 ms)
or no bus connection
or CAN error passive level (max. 128 retries)
11