Inertial Measurement Unit IMUF99*B20
Example
Step 2: Send command factory reset
Identifier
Priority
PGN
0x00
0xEF80
Table 7.5
xx: unused, bytes optional
Effect
New parameter is acknowledged.
Message: D0 = parameter successfully written or read (see also chapter "J1939 Interface
Description", section "Answer Messages").
Yellow LED blinks
No more PDOs are sent
Step 3: Leaving Parameter Mode
See also chapter "Leaving Parameter Mode"
Identifier
Priority
PGN
0x00
0xEF80
Table 7.6
xx: unused, bytes optional
Effect
Parameter Mode is left.
Sensor restarts.
Factory default values are set again.
Yellow LED blinks
PDOs are sent
32
Data Bytes
Source
1
2
address
CMD
Index
0x01
0xE2
0x00
(CMD:
(CMD:
Factory
Factory
reset)
reset)
Data Bytes
Source
1
2
address
CMD
Pass-
word
0x01
0xEB
0x00
3
4
5
xx
xx
xx
3
4
5
xx
xx
xx
6
7
8
xx
xx
xx
6
7
8
xx
xx
xx