Inertial Measurement Unit IMUF99*B20
Parameter Table
Index
Name
0x8B
Param_AF_In-
cl_z_SP2
0x8C
Param_AF_In-
cl_z_Logic
Table 8.1
1)
PDO according to table in chapter "PDO Mapping"
2)
Filter Type according to table in chapter "Filter Settings"
52
Valid values
Default value
0 ... 36000
0
0, 1
0
Size
[bytes] Description
2
Just use it in combination with
INX/INY/INZ inclination setting.
Don't use it with ZYZ or zy'x'' incli-
nation setting.
For inclination z-axis:
The value of this switching point
parameter determines the Limit2,
exceeding or falling below it leads to
a change in the switching status for
the application flag. The value of
Limit2 can be chosen inde-
pendently of Limit1.
1
Just use it in combination with
INX/INY/INZ inclination setting.
Don't use it with ZYZ or zy'x'' incli-
nation setting.
For inclination z-axis:
This parameter determines which
value range of the limits should be
displayed as the "active" value
range.
•
0 = low active:
In single point mode - if the value
falls below Limit1 (independent of
sign), AF is set to "low". If Limit1 is
exceeded (independent of sign), AF
is set to "high".
In window mode - If the value is
between Limit1 and Limit2, AF is set
to "low". If the value is outside of
Limit1 and Limit2, AF is set to
"high".
•
1 = high active:
In single point mode - if the value
falls below Limit1 (independent of
sign), AF is set to "high". If Limit1 is
exceeded (independent of sign), AF
is set to "low".
In window mode - If the value is
between Limit1 and Limit2, AF is set
to "high". If the value is outside of
Limit1 and Limit2, AF is set to "low".