15.3
Parameter setting group handling
15.3.1
Identification
Function description
Setting group handling
Parameter setting groups
15.3.2
Application
Four different groups of settings are available to optimize IED operation for different power
system conditions. By creating and switching between fine tuned setting sets, either from the
local HMI or configurable binary inputs, results in a highly adaptable IED that can cope with a
variety of power system scenarios.
Different conditions in networks with different voltage levels require highly adaptable protection
and control IEDs to best provide for dependability, security and selectivity requirements.
Protection IEDs operate with a higher degree of availability, especially, if the setting values of their
parameters are continuously optimized according to the conditions in the power system.
Operational departments can plan for different operating conditions in the primary power system
equipment. The protection engineer can prepare the necessary optimized and pre-tested settings
in advance for different protection functions. different groups of setting parameters are available
in the IED. Any of them can be activated through the different programmable binary inputs by
means of external or internal control signals.
The four different groups of setting parameters are available in the IED. Any of them can be
activated through different inputs by means of external programmable binary or internal control
signals.
15.3.3
Setting guidelines
The setting
can also be selected with configured input to the function block ACTVGRP.
The parameter
between. Only the selected number of setting groups will be available in the Parameter Setting
tool (PST) for activation with the ACTVGRP function block.
15.4
Test mode functionality TESTMODE
15.4.1
Identification
Function description
Test mode functionality
Busbar protection REB650
Application manual
IEC 61850
identification
SETGRPS
ACTVGRP
ActiveSetGrp , is used to select which parameter group to be active. The active group
MaxNoSetGrp defines the maximum number of setting groups in use to switch
IEC 61850
identification
TESTMODE
© Copyright 2013 ABB. All rights reserved
IEC 60617
ANSI/IEEE C37.2
identification
device number
-
-
-
-
IEC 60617
ANSI/IEEE C37.2
identification
device number
-
-
Section 15
Basic IED functions
GUID-75DF4E62-D690-4AE4-9330-E9C9A35EFFC8 v1
M12007-6 v8
M15259-3 v3
GUID-0411129B-3A42-4A3B-A8E7-178D0EA5A7EA v2
227

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reb650

Table of Contents