Chapter 6 Operations and Measurements
Press Operation continuously to enable or disable the "BandStop" operation
function.
Press SourceA, and rotate the multifunction knob
SourceA. Then press down the knob to select the channel. You can also press
SourceA continuously or enable the touch screen to select the channel. The
available channels for SourceA are CH1-CH4 and Ref1-Ref10.
Note:
The source of Math2 can be CH1-CH4, Ref1-Ref10, or Math1; the source
of Math3 can be CH1-CH4, Ref1-Ref10, Math1, or Math2; the source of
Math4 can be CH1-CH4, Ref1-Ref10, Math1, Math2, or Math3; only the
channels that have been enabled currently can be selected.
Press Offset to set the vertical offset of the operation results. For setting
methods, refer to the descriptions in "Parameter Setting Method". You can
also directly rotate Wave Vertical
to adjust the vertical offset.
Press Scale to set the vertical scale of the operation results. For setting methods,
refer to the descriptions in "Parameter Setting Method". You can also
directly rotate Wave Vertical
the vertical scale.
Press AutoSetting to adjust the vertical scale and offset of the operation
results to an optimal value based on the current configuration, so as to better
observe.
Press More → ωc1 to set the lower limit frequency. For setting methods, refer
to descriptions in "Parameter Setting Method".
Press More → ωc2 to set the upper limit frequency. For setting methods, refer
to descriptions in "Parameter Setting Method".
Note:
The settable ranges of the upper and lower limit frequencies are related
to the Math sample rate (displayed at the bottom of the screen when the
Math function is enabled). The sample rate of the analog channel or the
changes of the memory depth can affect the Math sample rate.
Press More → Invert to enable or disable the inverted display function of the
waveform.
Press More → Label to set the label for math operation results. For details,
refer to descriptions in "Math Operation Label".
Press More → Color Grade to enable or disable the color grade display of the
operation results. When enabled, different colors are displayed on the screen to
indicate the times of data acquisition or acquisition probability.
Press More → Reset ColorGrade to clear the color grade display and display
the color grade again.
MSO8000 User Guide
POSITION or enable the touch screen
SCALE or enable the touch screen to adjust
RIGOL
to select the channel for
6-25