Operation

Do not operate the system with any enclosure panels removed or damaged and do not touch any
parts of the pump(s) when the system is on. Surfaces of the pump(s) are very hot and can cause
injury to people.
Do not operate the system with any enclosures removed or damaged. If you do there may be a risk
of an electric shock.
4.1

Start-up

Ensure that it is safe to start the system. If you do not (and, for example, maintenance is being
performed on components downstream of the system), you could cause injury to people.
After the power is applied, all mains circuits will be energised.
The system is designed to ride through short term power interruption and to automatically restart once the
power is restored.
Do not operate the pump if the exhaust pipeline is restricted or blocked as the pump will not operate correctly
and may be damaged.
1. Switch on the electrical supply.
2. Switch on the cooling-water supply.
3. Check that the exhaust-extraction system is not restricted, and that any valves in the exhaust-extraction system
are open.
The pump can be started using the front panel control, the MicroTIM or the PDT.
Front control panel operation:
4. To operate the system using the front control panel (refer to
Press and hold the 'Local Control' button
taken. The message 'Keys in Control' will be displayed on the PDT if connected.
Press and hold the Start button
illuminated.
© Edwards Limited 2010. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
WARNING
WARNING
WARNING
WARNING
CAUTION
CAUTION
(Figure
3, item 3). The Green LED will illuminate when control is
(Figure
3, item 1) until pumps starts and the Running LED
Figure
3);
A541-11-880 Issue A
(Figure
3, item 1) is