Stacking The Ixl120 System - Edwards iXL120N Instruction Manual

Dry pump system
Table of Contents

Advertisement

A541-11-880 Issue A
3.4

Stacking the iXL120 system

You must use suitable lifting equipment to move the system. It is too heavy to lift by hand.
Do not exceed the topple angle of 10° when moving the pump. Wheel the system on its castors to
move it into its operating position. The system should only be wheeled short distances over flat
surfaces. If the floor surface is uneven or has obstacles the system should be lifted with suitable
lifting equipment.
The iXL120 system is designed so that one pump can be stacked on top of one other pump.
1. Remove the iXL120 system
from its packaging as
shown in
Section
3.2.
3. Reattach the brackets at
the front right and rear
left corners using two
fixings for each bracket.
4. Position the pump as
required using suitable
lifting equipment. This is
the base pump.
7. Using the lifting
equipment, position the
top pump above the base
pump.
8. Slowly lower the top pump
so that it rests on top of
the base pump, and inside
of the fixing brackets.
Page 16
WARNING
WARNING
2. Remove the brackets
from their stored
position at the base of
the pump.
5. Attach the brackets to
the top pump (as
described above) and
lift to shoulder height.
6. Wind up jacking feet
until flush with
bottom of chassis.
9. Attach the top pump
to the fixing brackets
using one fixing for
each bracket.
10. Remove the lifting
equipment and the
lifting brackets from
the top pump.