Edwards iXL120N Instruction Manual page 16

Dry pump system
Table of Contents

Advertisement

A541-11-880 Issue A
Electrical sub-system: continuous / 100% full load ratings
Input supply
Input supply
voltage
frequency
(V) (a.c., rms)
(Hz)
200
50
200
60
240
50
240
60
380
50
380
60
460
50
460
60
*
The electrical sub-system ratings, detailed in
The displayed power consumption, in
internal auxiliary power-supply. This auxiliary power-supply is used to power the pump's motor-controller,
pump-controller and customer accessories.
Table 7 - Electrical ratings: over-load condition (175% full load for 60s)
Electrical sub-system: over-load ratings
Input supply
Input supply
voltage
frequency
(Hz)
(V) (a.c., rms)
200
50
200
60
240
50
240
60
380
50
380
60
460
50
460
60
*
The electrical sub-system ratings, detailed in
The Displayed Power consumption, in
internal auxiliary power-supply. This auxiliary power-supply is used to power the pump's motor-controller,
pump-controller and customer accessories.
Page 8
Table 6 - Electrical ratings: full load conditions
Input supply current
(A)
(A) (a.c., rms)
(Repetitive
Peak)
9.5
36.2
10.4
38.9
9.3
35.8
9.0
33.7
5.8
22.5
5.7
21.5
4.8
18.8
4.8
18.1
Table
6, assume an input short-circuit rating of 30 kA.
Table
6, does NOT include the power consumption of the pump's
*
Input supply current
(A)
(A) (a.c., rms)
(Repetitive
peak)
15.1
52.9
15.3
54.1
13.4
49.2
14.5
52.8
9.9
36.6
9.6
34.6
8.2
30.2
8.0
28.9
Table
7, assume an input short-circuit rating of 30 kA.
Table
7, does NOT include the power consumption of the pump's
Edwards and the Edwards logo are trademarks of Edwards Limited.
*
Input supply
power
(kW)
1.65
1.65
1.65
1.65
1.65
1.65
1.65
1.65
Input supply
Displayed power / motor power
power
(kW)
2.85
2.85
2.85
2.85
2.85
2.85
2.85
2.85
© Edwards Limited 2010. All rights reserved.
Displayed power / motor
power
(kW)
1.53
1.53
1.53
1.53
1.53
1.53
1.53
1.53
(kW)
2.62
2.62
2.62
2.62
2.62
2.62
2.62
2.62